
Clean Fuel Vehicle Performance Test Service Unit provides performance and efficiency testing services for electric vehicles and vehicles using petroleum fuels, including being a prototype for research projects on clean fuel energy that is environmentally friendly. The main testing tools are the Chassis Dynamometer and the Engine Combustion Exhaust Analyzer. The service unit provides measurement and testing services in accordance with the announcement of the Department of Land Transport on determining the power of electric motors used to drive vehicles according to the Motor Vehicle Act B.E. 2563 for all types of electric vehicles, such as modified electric motorcycles, modified electric tuk-tuks, and modified electric cars, etc.
เนื่องจากในปัจจุบันมีการเจริญเติบโตทางด้านอุตสาหกรรม เทคโนโลยี เศรษฐกิจ การขนส่ง และการคมนาคมเป็นอย่างมาก ทำให้มีการใช้รถยนต์สำหรับการคมนาคมและขนส่งอย่างมากมาย ทั้งรถยนต์นั่งส่วนบุคคล และรถยนต์นั่งสาธารณะ เช่น รถแท็กซี่และรถตุ๊กๆนั่นเอง ซึ่งจากข้อมูลเมื่อปี 2556 ในกรุงเทพมหานคร มีรถแท็กซี่ประมาณ 120,000 คัน ในจำนวนนี้มีรถแท็กซี่ที่จดทะเบียนในเขตกรุงเทพมหานครจำนวนทั้งสิ้น 108,616 คัน แต่มีรถแท็กซี่ที่ผ่านการตรวจสอบมาตรฐานคุณภาพตัวรถตามที่กรมการขนส่งทางบกกำหนด จำนวน 24,859 คัน หรือคิดเป็น 23 % ของจำนวนรถแท็กซี่ที่จดทะเบียนในเขตกรุงเทพมหานครเท่านั้น ทั้งนี้ในอนาคตอันใกล้ กลุ่มรถยนต์นั่งส่วนบุคคล และรถยนต์นั่งสาธารณะเหล่านี้จะถูกผลักดันจากนโยบายสนับสนุนของรัฐบาลให้เปลี่ยนมาเป็นรถยนต์ไฟฟ้าในจำนวนมาก เพื่อมาแทนยานยนต์ที่ใช้เชื้อเพลิงจากน้ำมันซึ่งจะเป็นแนวทางในการลดการนำเข้าน้ำมันดิบจากต่างประเทศ และช่วยลดมลพิษไอเสียที่เกิดขึ้นมาจากเครื่องยนต์สันดาปภายในเหล่านั้น ที่ส่งผลกระทบต่อการเกิดภาวะโลกร้อน (Global warming) โดยตรง ดังนั้นยานยนต์ไฟฟ้าปริมาณมากมายที่จะถูกนำมาใช้งานจริงบนท้องถนนต้องผ่านการตรวจสอบและทดสอบสมรรถนะอย่างถูกต้องตามเกณฑ์มาตรฐานจากกรมการขนส่งทางบกโดยตรง หรือจากหน่วยบริการวิชาการเฉพาะทางด้านการทดสอบสมรรถนะยานยนต์เชื้อเพลิงสะอาดที่ได้รับอนุญาตให้เป็นผู้แทนตรวจสภาพรถยนต์ไฟฟ้าได้ จึงเป็นมูลเหตุให้มีการจัดตั้งหน่วยบริการวิชาการเฉพาะทางด้านการทดสอบสมรรถนะยานยนต์เชื้อเพลิงสะอาดขึ้น เพื่อรองรับการการตรวจสอบและทดสอบสมรรถนะยานยนต์ไฟฟ้าตามเกณฑ์มาตรฐานจากกรมการขนส่งทางบก ซึ่งขณะนี้หน่วยบริการวิชาการเฉพาะทางด้านของเราได้มีความร่วมมือจากคณะวิทยาศาสตร์ คณะวิศวกรรมศาสตร์ วิทยาลัยนานาชาติและหน่วยงานภาครัฐและเอกชน อาทิเช่น กรมส่งเสริมอุตสาหกรรม ภาค 5, บริษัท ไทยคิงมอเตอร์ อินโนเวชั่น จำกัด, บริษัท เอ็ส บี เอ็ม เอ็นจิเนี่ยริ่ง จำกัด, บริษัท ช่วยราม เอ็นจิเนี่ยริ่ง จำกัด และสมาคมการค้ารถสามล้อส่วนบุคคล และมอเตอร์ไซค์ไฟฟ้า เพื่อสนับสนุนการตรวจสอบและทดสอบสมรรถนะยานยนต์ไฟฟ้า เช่น บริการทดสอบประสิทธิภาพกำลังงาน ประสิทธิภาพการเผาไหม้และค่าไอเสียของรถยนต์สันดาปภายใน รถยนต์นั่งสาธารณะ(รถแท็กซี่)ในกรุงเทพมหานคร โดยเฉพาะในเขตลาดกระบัง นอกจากนี้ยังจะเป็นการบูรณาการการศึกษาสำหรับการเรียนการสอนในรายวิชา 05106335 หน่วยปฏิบัติการทางอุตสาหกรรมปิโตรเคมี ของภาควิชาเคมี คณะวิทยาศาสตร์ ที่มีสาระสำคัญมุ่งเน้นให้ผู้เรียนได้รับการเรียนรู้การถ่ายโอนโมเมนตัม การไหลของอากาศ การดุลมวล โมเมนตัมและพลังงาน รายวิชาด้าน Software and Automotive Engineering ของภาควิชาวิศวกรรมเครื่องกล คณะวิศวกรรมศาสตร์ และวิทยาลัยนานาชาติ ได้เข้าเรียนรู้ และฝึกงานที่หน่วยบริการวิชาการเฉพาะทางด้านการทดสอบสมรรถนะยานยนต์เชื้อเพลิงสะอาด เพื่อเตรียมความพร้อมก่อนที่จะออกไปทำงานจริง ดังนั้น การเพิ่มพูนความรู้และประสบการณ์ในรายวิชาที่กำลังศึกษาจึงมีความสำคัญเป็นอย่างยิ่งต่อการพัฒนาองค์ความรู้ในเชิงปฏิบัติได้เป็นอย่างดี

คณะวิทยาศาสตร์
A new colorimetric assay for the rapid detection of tannic acid in beverage samples based on displacement phenomenon of aggregated gallic acid-modified platinum nanoparticles is developed for the first time. PtNPs were functionalized with gallic acid, promoting the formation of the green-hued aggregated nanoparticles. While colorimetry offers a rapid method for identifying tannic acid, challenges remain in sensitivity and accuracy of detection on the PtNPs colorimetric probe, particularly in the presence of anthocyanin interferences. To address this, we developed a sample preparation method to degrade anthocyanin in beverages. Tannic acid was easily displaced onto the gallic acid-coated PtNPs surfaces, causing dispersion and resulting in a visible color change from green to orange−brown. Under the optimal conditions, the colorimetric sensor exhibited a linear response in the range of 1−2,000 µmol L−1 (R2 = 0.9991). The limit of detection (LOD) and the limit of quantification (LOQ) were found at 0.02 and 0.09 µmol L−1, respectively. The proposed sensor expressed superior selectivity over other interfering substances and demonstrated excellent precision with a relative standard deviation (RSD) of 1.00%−3.36%. More importantly, recoveries ranging from 95.0−104.7% were obtained, indicating the capability of proposed colorimetric sensor to detect tannic acid rapidly and accurately in real beverage samples.

คณะแพทยศาสตร์
Background: The RGL3 gene plays a role in key signal transduction pathways and has been implicated in hypertension risk through the identification of a copy number variant deletion in exon 6. Genome-wide association studies have highlighted RGL3 as associated with hypertension, providing insights into the genetic underpinnings of the condition and its protective effects on cardiovascular health. Despite these findings, there is a lack of data that confirms the precise role of RGL3 in hypertension. Additionally, the functional impact of certain variants, particularly those classified as variants of uncertain significance, remains poorly understood. Objectives: This study aims to analyze alterations in the RGL3 protein structure caused by mutations and validate the location of the ligand binding sites. Methods: Clinical variants of the RGL3 gene were obtained from NCBI ClinVar. Variants of uncertain significance and likely benign were analyzed. Multiple sequence alignment was conducted using BioEdit v7.7.1. AlphaFold 2 predicted the wild-type and mutant 3D structures, followed by quality assessment via PROCHECK. Functional domain analysis of RasGEF, RASGEF_NTER, and RA domains was performed, and BIOVIA Discovery Studio Visualizer 2024 was used to evaluate structural and physicochemical changes. Results: The analysis of 81 RGL3 variants identified 5 likely benign and 76 variants of uncertain significance (VUS), all of which were missense mutations. Structural modeling using AlphaFold 2 revealed three key domains: RasGEF_NTER, RasGEF, and RA, where mutations induced conformational changes. Ramachandran plot validation confirmed 79.7% of residues in favored regions, indicating an overall reliable structure. Moreover, mutations within RasGEF and RA domains altered polarity, charge, and stability, suggesting potential functional disruptions. These findings provide insight into the structural consequences of RGL3 mutations, contributing to further functional assessments. Discussion & Conclusion: The identified RGL3 mutations induced physicochemical alterations in key domains, affecting charge, polarity, hydrophobicity, and flexibility. These changes likely disrupt interactions with Ras-like GTPases, impairing GDP-GTP exchange and cellular signaling. Structural analysis highlighted mutations in RasGEF and RA domains that may interfere with activation states, potentially affecting protein function and stability. These findings suggest that mutations in RGL3 could have functional consequences, emphasizing the need for further molecular and functional studies to explore their pathogenic potential.

คณะวิทยาศาสตร์
This research aims to select the location of the beverage distribution center of Thai Spirit Industry Co., Ltd. with the lowest total cost of transportation. using a mathematical model by considering the Muang districts of all 76 provinces, excluding Chachoengsao Province, where the factory is located. In the present study, four scenarios were divided: 1) when only one distribution center was required; 2) when more than one distribution center was established; 3) when it was divided into 4 regions. There can only be one distribution center in one region, and 4) when it is divided into four regions, where more than one distribution center can be established in one region. When processed with the program IBM ILOG CPLEX Optimization Studio, the results are summarized as follows: Scenario 1, when only one distribution center is assigned. The total transportation cost is 786,107.75 baht/month. Scenario 2, when more than one distribution center can be established. The total transportation cost is 252,338.98 baht/month. Scenario 3, when divided into 4 regions by requiring only one distribution center in one region. The total transportation cost is 401,499.61 baht/month. Scenario 4, when divided into 4 regions by requiring that there is more than one distribution center in each region. The total transportation cost is 258,666.22 baht/month.